The calibration measurement result is indicated by numeric values and graph.
Check the measurement result, and judge whether or not advanced calibration is required.
Category | Print Workflow, Adjustment / Maintenance | ||
Location | Machine | - | |
Printer driver | - | ||
Application | Color Centro | ||
Required options | - | ||
Required items | - | ||
Setting items | C / M / Y / K | Select this check box to display the measurement curve of the selected color in the graph. | |
[Measure] [D-Max] | Displays the [D-Max] measured at the time of calibration or [Accuracy Measurement]. [D-Max] refers to the maximum density. If the actual measured value is too lower than [D-Max], high-density colors may not be correctly output. If the actual measured value is too higher than [D-Max], the gradation may become rough. Data of 0% to 100% is output with a few steps (example: 0% to 80%). | ||
[Target] | Select this check box to display the target curve of the recommended paper for the selected paper type in the graph. | ||
[Density(before Calibration)] | Select this check box to display the uncalibrated measurement curve in the graph. | ||
[Density(after Calibration)] | Select this check box to display the calibrated measurement curve in the graph. | ||
[CMYK Density] graph | The following measurement curves are displayed. Target curve of recommended paper for paper type Uncalibrated data Calibrated data | ||
Remarks | - | ||
Reference | - | ||
Screen access | Color Centro - [Calibration] |