When performing a new automatic inspection, create a reference image before printing the job.
You can perform the same operation using AccurioPro Print Manager.
This then creates the reference image.
Prints out a single copy as proof.
If Inspection Enhancement Kit UK-311 is mounted, you can set RIP data to reference image. Proof printing is performed even if RIP data is selected for the reference images.
For variable printing, refer to Decoding and Checking Barcode and Serial No. Areas.
After successfully printing the proof copy, the printed data is registered as a reference image. The reference image has the same file name as the original.
The printed data is also registered and displayed as a reference image on the [MACHINE], [Ref. Image Manage.], and [Reference Image List 1] options on the system’s Touch panel. For details, refer to [Ref. Image Manage.] Screen.
If, after checking the contents, you want to recreate a reference image, repeat Step 1 through Step 9.
Item | Setting Value |
---|---|
[Inspection Level] | For example, select [Standard] |
[Reference Image] | Select [Use Registered Image], press [Change...], and on the subsequently displayed screen select the reference image registered in Step 9 |
The print job begins, followed by the automatic inspection.
If an abnormality is detected during the inspection, it is displayed on the [MACHINE] and [IQ Detected Result] screens on the system’s Touch panel. For details, refer to [IQ Detected Result].
You can check the automatic inspection reports using the system’s Touch panel or from Web Utilities on Auto Inspection Unit UK-301.