Set the reference image type for automatic inspection.
Category | Adjustment / Maintenance | ||
Location | Machine | Touch Panel | |
Printer driver | - | ||
Application | - | ||
Required options | All the following optional devices are required. Intelligent Quality Optimizer IQ-501 Auto Inspection Unit UK-301 Relay Unit RU-702 Video Interface Kit VI-514 Video Interface Kit VI-515 Inspection Enhancement Kit UK-311 | ||
Required items | - | ||
Setting items | -[RIP Data] | Saves the RGB image created by the image controller as a reference image. The black background contained in the scanned image is deleted, so the high-precision automatic inspection becomes possible. | |
[Scan Image] | Saves the image scanned by Intelligent Quality Optimizer IQ-501 as a reference image. | ||
Remarks | -: Default | ||
Reference | - | ||
Screen access | Control panel - Utility/Counter - [User Setting] - [Common Setting] - [Reference Image Type Selection] | ||
Control panel - Utility/Counter - [Administrator Setting] - [Common Setting] - [Reference Image Type Selection] |