Change the settings detailed below in order to reduce the number of spoiled sheets (paper that need to be disposed) generated when performing adjustments. For details about configuring the settings of the various functions, refer to the reference page.
Setting item | Setting | With Intelligent Quality Optimizer IQ-501 Mounted | Without Intelligent Quality Optimizer IQ-501 Mounted / With Relay Unit RU-518m Mounted | Without Intelligent Quality Optimizer IQ-501 Mounted / Without Relay Unit RU-518m Mounted |
---|---|---|---|---|
[Color Density Control] - [Basic Setting] | ||||
[Use Color Density Control] | [ON] | . | . | e |
[Periodical Adj. Execution] | [ON] | . | . | e |
[Adjustment Execution Timing] | [Before Job Start] | . | . | e |
[Switch Color(1st or 2nd)] | [Normal] | . | . | e |
[Adjustment Interval] | [OFF] | . | . | e |
For details about Exact Color Calibration, refer to About Calibration Using [Exact Color].
For details about G7 Calibration, refer to About Calibration Using [G7].
Setting Item | Setting | With Intelligent Quality Optimizer IQ-501 Mounted | Without Intelligent Quality Optimizer IQ-501 Mounted / With Relay Unit RU-518m Mounted |
---|---|---|---|
[Auto Selection] | OFF | . | e |
[Simple Diagnosis] | Don't perform | . | e |
[Detailed Diagnosis] | Don't perform | . | e |
[Density Balance Auto. Adjustment] | Perform | . | e |
[Max. Density Auto Adj.] | Perform using the specified paper | . | e |
[Color Density Control] | Perform using the specified paper | . | e |
[Exact Color]/[G7] | Perform using the specified paper | . | e |
If there are any issues with the image quality, make the additional adjustments detailed below.
Set [Auto Selection] to ON for [Package Color Auto Adj.], execute [Image Diagnosis], and then adjust the items that are available except for controller calibration items such as [Exact Color] and [G7]. For details about [Image Diagnosis], refer to [Image Diagnosis].
Setting Item | Setting | With Intelligent Quality Optimizer IQ-501 Mounted | Without Intelligent Quality Optimizer IQ-501 Mounted / With Relay Unit RU-518m Mounted |
---|---|---|---|
[Auto Selection] | ON | . | e |
When performing [Color Density Manual Control], be sure to first set [Periodical Adj. Execution] to [OFF]. For details about [Periodical Adj. Execution], refer to [Basic Setting].
Setting Item | Setting | With Intelligent Quality Optimizer IQ-501 Mounted | Without Intelligent Quality Optimizer IQ-501 Mounted / With Relay Unit RU-518m Mounted |
---|---|---|---|
Perform at user discretion | - | . |