Read the output chart using Intelligent Quality Optimizer IQ-501, and automatically perform Both Sides Adjustment. Up to 20 charts can be automatically read at one time. As the number of charts is greater, the accuracy of the adjustment value becomes higher.
The result is displayed after adjustment so you can immediately grasp the adjustment result.
Category | Copy / Scan | ||
Location | Machine | Touch Panel | |
Printer driver | - | ||
Application | - | ||
Required options | Intelligent Quality Optimizer IQ-501 | ||
Required items | - | ||
Setting items | / | Once locked, you cannot manually change the numeric value of [Back] in [Vertical] and [Horizontal]. The numeric value of the front side cannot be updated by automatic measurement. | |
[Vertical] | Set the vertical magnification of the back or front side. | ||
[Horizontal] | Set the horizontal magnification of the back or front side. | ||
[Up/Down Shift] | Set the amount to vertically shift an image on the back or front side. Shift target: Image + Crop mark | ||
[Right/Left Shift] | Set the amount to horizontally shift an image on the back or front side. Shift target: Image + Crop mark | ||
[Up/Down Shift (Img.)] | Set the amount to vertically shift an image on the back or front side. Shift target: Image only | ||
[Right/Left Shif (Img.)] | Set the amount to horizontally shift an image on the back or front side. Shift target: Image only | ||
[Rotate] | Displays each adjustment value. To update the numeric value, perform [AutoMeasure]. | ||
[Skew] | |||
[Trapezoid(CD)] | |||
[Trapezoid(FD)] | |||
[Curve] | |||
[Peak of Curve] | |||
[Print Mode] | Outputs a chart for measurement. | ||
Remarks | - | ||
Reference | - | ||
Screen access | Touch panel - [MACHINE] - [Paper Setting] - [Both Sides] - [Change Set] - [Both Sides Adj.] - [AutoMeasure] | ||
Touch panel - [MACHINE] - [Paper Setting] - [New Setting] - [Both Sides Adj.] - [AutoMeasure] | |||
Touch panel - [MACHINE] - [Both Sides] - [AutoMeasure] | |||
Touch panel - [MACHINE] - [Reg./Del.PaperSet.] - [Add/Edit] - [Both Sides Adj.] - [AutoMeasure] |
A test chart is output, and each adjustment value is updated.
Use [+ / -] to select the positive or negative value.
To enlarge the print image, enter a positive value, and to reduce it, enter a negative value.
Adjustment range: [-1.00~+1.00]
Use [+ / -] to select the positive or negative value.
To shift the print image (image and crop mark) up or to the right, enter a positive value, and to shift it down or to the left, enter a negative value.
Adjustment range (Vertical): [-10.0~+10.0]
Adjustment range (Horizontal): [-3.0~+3.0]
Use [+ / -] to select the positive or negative value.
To shift the print image (image only) up or to the right, enter a positive value, and to shift it down or to the left, enter a negative value.
Adjustment range (Vertical): [-10.0~+10.0]
Adjustment range (Horizontal): [-3.0~+3.0]