Adjust the perforation position in the crosswise direction.
Category | Adjustment / Maintenance | ||
Location | Machine | Touch Panel | |
Printer driver | - | ||
Application | - | ||
Required options | Trimmer Unit TU-510 with Perforation Unit PE-102 mounted | ||
Required items | - | ||
Setting items | [Position] | Select the perforation position in the crosswise direction. | |
[Front Length] | Select the jump position before a perforation in the crosswise direction. Adjust this when shifting occurs at the second position before the perforation in the crosswise direction with [Four Edge Trim Mode]. | ||
[Rear Length] | Select the jump position behind the perforation in the crosswise direction. Adjust this when shifting occurs at the second position behind the perforation in the crosswise direction with [Four Edge Trim Mode]. | ||
Perforation timing selection key | Select what numbered perforation position is adjusted. | ||
Keypad | Used to enter numeric values. | ||
[Clear] | Returns the entered numeric value to "0". | ||
[Set] | Sets the numeric value entered using the keypad to the selected setting item. | ||
Remarks | - | ||
Reference | - | ||
Screen access | Touch panel - [MACHINE] - [Adjustment] - [Finisher Adjustment] - [Trimmer Unit Adjustment] - [Finishing Position Adj.] - [Four Edge Trim Mode] - [CD Perforation Position] | ||
Control panel - Utility/Counter - [Administrator Setting] - [System Setting] - [Expert Adjustment] - [Finisher Adjustment] - [Trimmer Unit Adjustment] - [Finishing Position Adj.] - [Four Edge Trim Mode] - [CD Perforation Position] |
If a trimmer profile is set, you can only select the same paper size as the size set in the trimmer profile.
Only when the trimmer profile is set, trimming can be set in [Trim] of [Output Setting].
A sample is output.
Use [+ / -] to select the plus or minus of the numeric value. To change [Current Data], press [Set].
(-) To move the perforation position to the lead edge (+) To move the perforation position to the rear edge
[Adj. Range:-50~+50 1step = 0.1mm]
Use [+ / -] to select the plus or minus of the numeric value. To change [Current Data], press [Set].
(-) To shorten the perforation, (+) To lengthen the perforation
[Adj. Range:-50~+50 1step = 0.1mm]
Use [+ / -] to select the plus or minus of the numeric value. To change [Current Data], press [Set].
(-) To shorten the perforation, (+) To lengthen the perforation
[Adj. Range:-50~+50 1step = 0.1mm]